home *** CD-ROM | disk | FTP | other *** search
/ The Arsenal Files 6 / The Arsenal Files 6 (Arsenal Computer).ISO / health / med9604b.zip / M9640733.TXT < prev    next >
Text File  |  1996-03-04  |  3KB  |  41 lines

  1.        Document 0733
  2.  DOCN  M9640733
  3.  TI    A manual bead assay for the determination of absolute CD4+ and CD8+
  4.        lymphocyte counts in human immunodeficiency virus-infected individuals.
  5.  DT    9604
  6.  AU    Carella AV; Moss MW; Provost V; Quinn TC; Department of Medicine, Johns
  7.        Hopkins University School of; Medicine, Baltimore, Maryland, USA.
  8.  SO    Clin Diagn Lab Immunol. 1995 Sep;2(5):623-5. Unique Identifier :
  9.        AIDSLINE MED/96089402
  10.  AB    CD4+ T lymphocytes are currently the most common surrogate marker
  11.        indicating disease progression in individuals infected with human
  12.        immunodeficiency virus (HIV). Since the cost of enumerating lymphocyte
  13.        phenotypes is quite high, an inexpensive bead assay analyzed by light
  14.        microscopy (cytosphere assay; Coulter Corporation, Hialeah, Fla.) was
  15.        developed as an alternative method for counting CD4+ and CD8+ T
  16.        lymphocytes. To evaluate the reliability of the cytosphere assay,
  17.        heparinized blood was collected from 117 HIV-infected individuals and
  18.        tested for both CD4+ and CD8+ lymphocytes by flow cytometry and the
  19.        cytosphere assay. The Pearson correlation coefficient of the cytosphere
  20.        assay compared with that of flow cytometry for CD4+ T lymphocytes was
  21.        0.93, with mean values +/- standard deviations of 534 +/- 509 by flow
  22.        cytometry and 499 +/- 477 by the cytosphere assay. The correlation
  23.        coefficient for CD8+ T lymphocytes was 0.86, with mean values of 831 +/-
  24.        543 by flow cytometry and 746 +/- 472 by the cytosphere assay. The
  25.        sensitivity and specificity of the cytosphere assay in determining
  26.        absolute CD4+ T-lymphocyte counts of less than 200/microliters were 97.6
  27.        and 94.7%, respectively. The positive predictive value was 90.9%, and
  28.        the negative predictive value was 98.6%. The cytosphere assay was highly
  29.        correlative to flow cytometry in determining CD4+ and CD8+ T-lymphocyte
  30.        counts among HIV-infected patients. The ease and limited resources
  31.        needed to perform this test make it ideal in developing countries and
  32.        other areas where technology and finances are limited.
  33.  DE    Cell Separation/*METHODS  Comparative Study  CD4 Lymphocyte
  34.        Count/*METHODS  CD8-Positive T-Lymphocytes/*IMMUNOLOGY  Flow Cytometry
  35.        Human  HIV Infections/*BLOOD/IMMUNOLOGY  Microspheres  Reproducibility
  36.        of Results  JOURNAL ARTICLE
  37.  
  38.        SOURCE: National Library of Medicine.  NOTICE: This material may be